Dispensing Booth, LCBT-10Z
Rated air volume: 1000 m³/h
Sterilization: 20 W
Supply wind speed: 0.45~0.5 m/s
Control: Adjustable wind speed, manual switch
Medium efficiency filter: Efficiency F8
High efficiency filter: Efficiency H13
Dispensing Booth, LCBT-40S
Rated air volume: 4500 m³/h
Supply wind speed: 0.45~0.5 m/s
Touch key switch control
Pre-filter: Efficiency G4
Medium efficiency filter: Efficiency F8
High efficiency filter: Efficiency H13
Dispensing Booth, LCBT-1200S
Polymer flow uniform membrane
Three-stage filtration of primary, intermediate and high-efficiency filters is adopted. < br> Digital touch display, frequency conversion control, air volume display, differential pressure display.
PCR Cabinet, LCB-VII Series
Energy-efficient DC blower
HEPA filter (ISO Class 3 work-zone)
Antimicrobial powder coating Displays all safety information on LCD screen
Standby mode for more energy savings
Programmable UV timer to extend the UV lamp lifespan
Laminar Flow Cabinet, Horizontal Type, Medical type, LCB-H1600J
Cleanliness level: ISO Class 5 (Class 100)
Downflow velocity: 0.25-0.6m/(adjustable)
With reasonable and safe structure design
Adopts aluminum frame high-efficiency filter
High-quality stainless steel, corrosion-resistant
Laminar Flow Cabinet, Horizontal Type, Medical type, LCB-H800J
Cleanliness level: ISO Class 5 (Class 100)
Downflow velocity: 0.2-0.5m/(adjustable)
With reasonable and safe structure design
Adopts aluminum frame high-efficiency filter
High-quality stainless steel, corrosion-resistant
Horizontal Laminar Flow Hood, LCB-HF Series
Work Surface Height: 750mm
Airflow Velocity: Adjustable, 0.2~0.5 m/s
HEPA Filter Efficiency: > 99.995% at particle size of 0.3 μm
Control System: Microprocessor controller with LCD display
Class II Type B2 Biosafety Cabinets, BSC-IIB2-5J
Cleanliness level: ISO level 4
Classification: Class II Type B2
Air flow mode: 100% discharge, 0 internal circulation
Vertical laminar negative pressure model
Working zone size: 1600*520*640mm
Class II Type A2 Biosafety Cabinets, BSC-IIA2-5J
Cleanliness level: ISO level 4
Classification: Class II Type A2
Air flow mode: 30% discharge, 70% internal circulation
Vertical laminar negative pressure model
Working zone area: 1600*520*640 mm
Class II Type B2 Biosafety Cabinets, BSC-IIB2-3J
Cleanliness level: ISO level 4
Classification: Class II Type B2
Air flow mode: 100% discharge, 0 internal circulation
Vertical laminar negative pressure model
Working zone size: 1000*520*640 mm
Class II Type A2 Biosafety Cabinets, BSC-IIA2-3J
Cleanliness level: ISO level 4
Classification: Class II Type A2
Air flow mode: 30% discharge, 70% internal circulation
Vertical laminar negative pressure model
Working zone size: 1000*520*640 mm
Laminar Flow Cabinet, Vertical type, Medical type, LCB-V1400J
Cleanliness level : ISO Class 5 (Class 100)
Downflow velocity: 0.25-0.6 m/s (adjustable)
Double-person and single surface
Intelligent LCD displays system parameters
With reasonable and safe structure design