DALPHIL DUNAMIS LTD
Visit our medical equipment website 
Here
Enquiries
Automobile Exhaust Analyzer, AEA-H500
Measure HC, CO, CO2,O2 and NOx gas concentrations;
German imports of infrared detector, O2and NOX sensor.
Measuring gasoline, LPG, CNG, alcohol and diesel fuel;
BAR97standards, ISO3930 or OIMLR99 I level precision;
Built-in printer (or the analog output interface or or Bluetooth/ RS232)

◆The large screen liquid crystal display, ( Chinese or English ) menu;
◆The use of German imports of infrared detector, O2and NOX sensor, vibration resistance, good stability, high precision;
◆The measurement of CO, HC, CO2for O2, NOX, COcor, concentration and the lambda value, speed, temperature, flow, pressure;
◆With the single, double idle idle, general measuring function;
◆Vehicles capable of measuring gasoline, LPG, CNG, alcohol and diesel fuel;
◆According to the new standard and the United States BAR97standards development, in line with the ISO3930or OIMLR99 I level precision;
◆With the automatic zero adjustment, automatic cleaning, automatic temperature compensation, pressure compensation;
◆With the HC residue measurement, traffic monitoring, gas leak check;
◆The machine has self diagnostic function, fault when prompted, until the troubleshooting can continue measurement;
◆With speed, temperature measurement, built-in printer or digital (Analog ) interface network;
◆The license plate number input and 500 groups of data storage, reference function, clock display;

Specifications

Measuring rangeHC: 0~10000×10-6(ppm)vol
CO: 0~10×10-2(%)vol )
CO2: 0~20×10-2(%)vol
O2: 0~25×10-2(%)vol
NOx: 0~5000×10-6(ppm)vol
R.M.P: 0~9999r.m.p
OIL TEMP:0~150℃
Lambda: 0.50~3.00
COcor:0~10×10-2(%)vol
Indicating errorHC±12×10-6(ppm)vol ( absolute error ) or±5% ( relative error )
CO±0.06×10-2(%)vol ( absolute error ) or±5% ( relative error )
CO2±0.5×10-2(%)vol ( absolute error ) or±5% ( relative error )
O2±0.1×10-2(%)vol ( absolute error ) or±5% ( relative error )
NOx±25×10-6 (ppm)vol ( absolute error ) or±4% ( relative error )
Stabilitymoment drift≤±3%
Repeatability≤±2%
ResolutionHC:1*106(ppm)vol
CO: 0.01*102(%)vol
CO2: 0.1*102(%)vol
O2: 0.01*102(%)vol
NOx: 1×10-6(ppm)vol
Lambda: 0.01
R.P.M:10r.p.m,
OIL TEMP:0.1℃
Response time95% response is not more than 10 seconds
Preheating time8min ( preheating 3min emergency detection )
Output modedigital direct reading, gases can be attached printer name, the maximum concentration, average value, minimum value, test time, date. Can interface with computer networking
And-use temperature -5~50°C,
Relative humidity≤90%
PowerAC100~240V 50/60Hz or DC12V( Add power inverter)
Power consumption40VA
Dimension420 (L )*310(W)*170(H)mm
Weight9kg
Scroll to Top