DALPHIL DUNAMIS LTD
Visit our medical equipment website 
Here
Enquiries
AEA-H500 Automobile-exhaust-analyzer
Measure HC, CO, CO2,O2 and NOx gas concentrations;
Automatically calculate and display the air-fuel ratio λ.
Free idle, double idle and multi working condition measurement
Auto-alarm when the gas line blocking
Built-in printer

1. It is used to measure the concentration of HC, Co, CO2, O2 and NOx in the exhaust gas of automobile.
2. It can automatically calculate and display the air-fuel ratio λ.
3. It can comprehensively detect the combustion performance and emission pollution of engine.
4. Using foreign advanced technology, Germany imported movement.
5. It has high brightness digital display, automatic zero calibration, automatic data linearization processing, automatic alarm in case of gas path blockage, and automatic diagnosis unit in case of fault.
6. The instrument is applicable to the detection of engine exhaust components using gasoline, LPG, CNG, alcohol and diesel as fuel.
7. It is equipped with built-in printer (or Bluetooth / RS232) to meet the new national standard gb18285-2018 and American bar-97 standard Accurate, in line with iso3930 or oimlr99 class I accuracy,
8. It can carry out free idle, double idle measurement and multi working condition measurement, with the characteristics of convenient operation, accurate measurement data, stable and reliable operation.

Specifications

Measuring rangeHC: 0~10000×10-6(ppm)vol
CO: 0~10×10-2(%)vol )
CO2: 0~20×10-2(%)vol
O2: 0~25×10-2(%)vol
NOx: 0~5000×10-6(ppm)vol
Lambda: 0.50~3.00
COcor:0~10×10-2(%)vol
Indicating errorHC±12×10-6(ppm)vol ( absolute error ) or±5% ( relative error )
CO±0.06×10-2(%)vol ( absolute error ) or±5% ( relative error )
CO2±0.5×10-2(%)vol ( absolute error ) or±5% ( relative error )
O2±0.1×10-2(%)vol ( absolute error ) or±5% ( relative error )
NOx±25×10-6 (ppm)vol ( absolute error ) or±4% ( relative error )
Stabilitymoment drift≤±3%
Repeatability≤±2%
ResolutionHC:1*106(ppm)vol
CO: 0.01*102(%)vol
CO2: 0.1*102(%)vol
O2: 0.01*102(%)vol
NOx: 1×10-6(ppm)vol
Lambda: 0.01
Response time95% response is not more than 10 seconds
Preheating time8min ( preheating 3min emergency detection )
Output modedigital direct reading, gases can be attached printer name, the maximum concentration, average value, minimum value, test time, date. Can interface with computer networking
Use temperature -5~50°C
Relative humidity≤90%
PowerAC100~240V 50/60Hz or DC12V( Add power inverter)
Power consumption40VA
Dimension420 (L )*310(W)*170(H)mm
Weight9kg

Note: Above absolute error and relative error can meet one of the requirements.