All components are controlled effectively via a Chromatographic Data-processing workstation
Automatically displays, prints, exports and starts other programs after the completion of a measurement
Integrated vacuum degasser with four channels
Multiple data analysis function, flexible peak identification and data management, etc
The monitoring system terminates the pump on exceeding its pre-limit pressure

Quaternary High Pressure Liquid Chromatography NHLC-300 is a quaternary pump chromatography system. It is composed of a low-pressure quaternary pump that delivers a combination of eluent under the controlled reciprocating valve. It is equipped with tungsten and deuterium lamp as a source of light and photo diode array as detector for precise separation and analysis of compounds with high operation reliability for extended time intervals.

Specifications

Quaternary Pump Specifications:- Flow rate Range0.001-10.000mL/min, 0.001mL increments
Flow accuracy≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precisionRSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Pressure accuracy≤ ±3.0%
Pressure pulsation≤0.1MPa
Composition range0-100%
Composition precision≤0.3% RSD
Composition accuracy≤±1.0%
Photo diode Array Detector Specifications:- Wavelength range190-760nm
Wavelength repeatability±0.1nm
Wavelength accuracy±1nm
Baseline noise≤ ±1.0×10-5AU (empty cell, 254nm, 1.0s)
Drift≤2.0×10-4AU/h (empty cell, 254nm, 60min)
Path length10mm
Dimensions (L×D×H)1620 × 1200 × 440 mm
Weight51kg

Features

  • ✔ Advanced and innovative design modules
  • ✔ Flexible System Configuration
  • ✔ Adjustable data collection frequency
  • ✔ Excellent optical path design improves the instrument signal to noise ratio
  • ✔ All components are controlled effectively via a Chromatographic Data-processing workstation
  • ✔ Automatically displays, prints, exports and starts other programs after the completion of a measurement
  • ✔ Integrated vacuum degasser with four channels
  • ✔ Multiple data analysis function, flexible peak identification and data management, etc
  • ✔ The monitoring system terminates the pump on exceeding its pre-limit pressure