DALPHIL DUNAMIS LTD
Visit our medical equipment website 
Here
Enquiries
Microwave Digestion/Extraction System, MDS-800-T40
Vessel Quantity:40 Vessel Volume:50mL
Temperature Monitoring :Contact-less IR sensor
7-inch touch screen display

Description

It is widely used in food, textile, geology, metallurgy, coal, biology, cosmetics, petrochemical, environment, waste water treatment, battery manufacturing fields, etc.

Features

  • Special designed sample digestion vessel

The automatic vent and self-resealing structure which won national patent ensures the digestion vessels can automatically release pressure and instantly reseal when a sudden over-pressure situation occurs.

  • Contact-ess temperature and pressure monitoring system

The advanced contact-less IR sensor could measure the real-time temperature of sample solutions in each digestion vessel. Meanwhile, the contact-less pressure sensor could monitor the real-time pressure of each vessel.

Each real-time temperature and pressure value is displayed during the whole digestion process, allowing a clear check of digestion conditions.

  • Large storage capacity

It can edit and store 255 types of programs according to user’ s requirements and each method program can set parameters (temperature, pressure, time, microwave power) according to their own requirements which provides convenient operation for users.

  • Safety Protection System

With high-strength double locked security door, the real-time temperature and pressure monitoring, automatic adjustment of over-pressure and over-temperature and abnormal sound monitoring, the device can run in a highly safe environment.

  • Power Adjustment

The variable frequency resonance or non-pulse(optional) continues rotating mode ensures high efficient and even microwave throughput. It can be set between 0~3000W according to user’ s requirements.

Specifications

ModelMDS-800-T40
Vessel Quantity40
Vessel Volume50mL
Temperature Monitoring SystemTemperature monitoring: Contactless IR sensorTemperature control:Scanning control of each vesselTemperature control range: 50~400℃;Temperature control accuracy:±0.3℃
Pressure Monitoring SystemContact-less pressure sensorPressure control range:0~10MPaPressure control accuracy:0.01MPa
Vessel MaterialInner: imported TFMOuter: imported PEEK+glass fiber
Display7-inch touch screen
Rotation Mode360° Continuous rotation
Microwave Power0-3000W adjustable
Microwave Leak<5mW/cm²
Microwave Frequency2450MHz
Max. Working Pressure6MPa
Max. Working Temperature250℃
Inner Vessel Temperature Limit300℃
ElectricityAC 220V, 16A, 50/60Hz
Dimension(L*W*H)640*630*590mm
N.W./G.W.78kg/155kg(Main device+Accessories)
Shipping Dimension(L*W*H)800*800*810mm (Main device), 620*590*560mm (Accessories)
Scroll to Top