Description
HM-1200 haze meter can easily achieve non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.
Advantages
Easy to operate, faster and more accurate measurement
The haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.
Dynamic measurement
Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.
With compensation port, so that the measurement data more accurate
Full light transmittance, fog test, provide more accurate test results.
Easy to measure and widely applicable to samples
Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.
Quality control software
It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.
Specifications
Model | HM-1200 |
Optical Geometry | Transmittance:0/D (Parallel light illumination, diffuse viewing); |
Integrating Sphere Size | Φ154mm |
Light Source | 400nm to 700nm, combined LED light source |
Sensor | The PD array detector satisfies CIE V(λ)2 degree visual response |
Measurement range | 0~100% |
Measuring Aperture | Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) |
Sample Size | Thickness <170mm |
Other Colorimetric Index | Haze,Transmittance T,Transmittance T |
Observer Angle | 2° |
Illuminant | D65,A,C |
Displayed Data | PASS/FAIL Result |
Measuring Time | About1.5s |
Resolution | 0.01unit |
Repeatability | Φ20mm,within 0.05 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) |
Inter-instrument Error | Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) |
Dimension(L*W*H) | 290*211*511mm |
Weight | About 7.6 kg |
Electricity | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Print serial port |
Data Storage | Standard 1000 pcs,sample 20000 pcs |
Language | Simplified Chinese,Traditional Chinese,English |
Operating Environment | 0~40℃(32~104°F) |
Storage Environment | -20~50℃(-4~122°F) |
Standard Accessory | Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. |
Optional Accessory | Micro-printer,Test fixture, standard haze sheet, foot switch |