DALPHIL DUNAMIS LTD
Visit our medical equipment website 
Here
Enquiries
Automobile Exhaust Analyzer, AEA-H400
1. Measure HC, CO, CO2,O2 gas concentrations
2.. Advanced international technology, import the key components assembled.
3. American bar-97 standard, ISO3930 or oimlr99.
4. HC residual measurement, flow monitoring and gas path leakage inspection.
5. Optional speed and oil temperature measurement

Description

  1. Large screen LCD display, Chinese (or English) menu;
  2. It adopts infrared detector and O2 sensor imported from Germany, which is not afraid of vibration, with good stability and high precision;
  3. It is used to measure Co, HC, CO2, O2 concentration and λ value, cocor, speed, oil temperature, flow rate and pressure;
  4. Single idle speed, double idle speed and general measurement function;
  5. It can measure the vehicles using gasoline, LPG, CNG and alcohol as fuel;
  6. It is developed according to the new national standard and American bar-97 standard, and meets the class I accuracy of iso3930 or oimlr99;
  7. Automatic zero adjustment, automatic cleaning, automatic temperature compensation and pressure compensation;
  8. It has HC residual measurement, flow monitoring and gas path leakage inspection;
  9. There is self diagnosis function in the machine, and there will be a prompt in case of fault, and the measurement can be continued until the fault is eliminated;
  10. Optional speed and oil temperature measurement, built-in printer or Bluetooth, RS232, analog interface;
  11. It can input the license plate number and store 500 groups of data. It has the function of reference and clock display

Specifications

Measuring rangeHC: 0~10000*10-6(ppm)vol
CO: 0~10*102(%)vol )
CO2: 0~20*102(%)vol
O2: 0~25*102(%)vol
R.P.M: 999r.m.p
OIL TEMP:0~150℃
Lambda:0.50~3.00
CO cor:0~10*102(%)vol
Indicating errorHC±12*10-6(ppm)vol ( absolute error ) or±5% ( relative error )
CO±0.06*102(%)vol ( absolute error ) or±5% ( relative error )
CO2±0.5*102(%)vol ( absolute error ) or±5% ( relative error )
O2±0.1*102(%)vol ( absolute error ) or±5% ( relative error )
Stabilitymoment drift≤±3%
Repeatability≤±2%
ResolutionHC:1*106(ppm)vol
CO: 0.01*102(%)vol
CO2: 0.1*102(%)vol
O2: 0.01*102(%)vol
Lambda: 0.01
R.P.M:10r.p.m,
OIL TEMP:0.1℃
Response time95% response is not more than 10 seconds
Preheating time8min ( preheating 3min emergency detection )
Output modedigital direct reading, gases can be attached printer name, the maximum concentration, average value, minimum value, test time, date. Can interface with computer networking
Use temperature -5~50°C,
Relative humidity≤90%
PowerAC100~240V 50/60Hz or DC12V( Add power inverter)
Power consumption40VA
Dimension420 (L )*310(W)*170(H)mm
Weight9kg