Description
- Large screen LCD display, Chinese (or English) menu;
- It adopts infrared detector and O2 sensor imported from Germany, which is not afraid of vibration, with good stability and high precision;
- It is used to measure Co, HC, CO2, O2 concentration and λ value, cocor, speed, oil temperature, flow rate and pressure;
- Single idle speed, double idle speed and general measurement function;
- It can measure the vehicles using gasoline, LPG, CNG and alcohol as fuel;
- It is developed according to the new national standard and American bar-97 standard, and meets the class I accuracy of iso3930 or oimlr99;
- Automatic zero adjustment, automatic cleaning, automatic temperature compensation and pressure compensation;
- It has HC residual measurement, flow monitoring and gas path leakage inspection;
- There is self diagnosis function in the machine, and there will be a prompt in case of fault, and the measurement can be continued until the fault is eliminated;
- Optional speed and oil temperature measurement, built-in printer or Bluetooth, RS232, analog interface;
- It can input the license plate number and store 500 groups of data. It has the function of reference and clock display
Specifications
| Measuring range | HC: 0~10000*10-6(ppm)vol |
| CO: 0~10*10–2(%)vol ) | |
| CO2: 0~20*10–2(%)vol | |
| O2: 0~25*10–2(%)vol | |
| R.P.M: 999r.m.p | |
| OIL TEMP:0~150℃ | |
| Lambda:0.50~3.00 | |
| CO cor:0~10*10–2(%)vol | |
| Indicating error | HC±12*10-6(ppm)vol ( absolute error ) or±5% ( relative error ) |
| CO±0.06*10–2(%)vol ( absolute error ) or±5% ( relative error ) | |
| CO2±0.5*10–2(%)vol ( absolute error ) or±5% ( relative error ) | |
| O2±0.1*10–2(%)vol ( absolute error ) or±5% ( relative error ) | |
| Stability | moment drift≤±3% |
| Repeatability | ≤±2% |
| Resolution | HC:1*10–6(ppm)vol |
| CO: 0.01*10–2(%)vol | |
| CO2: 0.1*10–2(%)vol | |
| O2: 0.01*10–2(%)vol | |
| Lambda: 0.01 | |
| R.P.M:10r.p.m, | |
| OIL TEMP:0.1℃ | |
| Response time | 95% response is not more than 10 seconds |
| Preheating time | 8min ( preheating 3min emergency detection ) |
| Output mode | digital direct reading, gases can be attached printer name, the maximum concentration, average value, minimum value, test time, date. Can interface with computer networking |
| Use temperature | -5~50°C, |
| Relative humidity | ≤90% |
| Power | AC100~240V 50/60Hz or DC12V( Add power inverter) |
| Power consumption | 40VA |
| Dimension | 420 (L )*310(W)*170(H)mm |
| Weight | 9kg |