DALPHIL DUNAMIS LTD
Visit our medical equipment website 
Here
Enquiries
Liquid Chromatograph Mass Spectrometer NLMS-100
High-speed scanning <
Efficient and easy automated calibration functions
Easy positive and negative ion mode switching
Easy ChemAnalyst Software interface
Multi-channel acquisition and full scan mode for rapid analysis
Isocratic High-performance Liquid Chromatography NHLC-200
Advanced and innovative design modules
All maintenance parts are accessible from the front panel for easy replacement without dismantling of the instrument
The monitoring system will terminate the pump on exceeding its pre-limit pressure
All components are controlled effectively via a workstation
Multiple data analysis function, flexible peak identification and data management, etc
Gradient High-performance Liquid Chromatography NHLC-100
Advanced and innovative design modules
All maintenance parts are accessible from the front panel for easy replacement without dismantling of the instrument
The monitoring system will terminate the pump on exceeding its pre-limit pressure
All components are controlled effectively via a workstation
Multiple data analysis function, flexible peak identification and data management, etc
High Performance Liquid Chromatograph, HPLC-3100
Detector: Diode Array Detector, UV-VIS Detector
Pump flow range: 0.001~10.000 ml/min
Inject volume range: 0~100 µL
Oven temp. range: Ambient + 5 ℃~85℃
High Performance liquid Chromatograph, HPLC-1100
Detector: UV/VIS
Detector wavelength: 190-700 nm
Pump flow rate: 0.001-10.000 mL/min
Oven temp.: R.T.+5 ℃~99 ℃
Gas Chromatograph, GC-901
Detector: FID, TCD, ECD, FPD, NPD
Temp control area: 8-way
16 Steps of procedure temp rising
Temp control range: RT -450°C
Speed ratio of range rising: 0.1-80℃/min
Gas Chromatograph, GC-900
Detector: FID, TCD, FPD
Temp control area: 7-way
20 steps of procedure temperature rising
Temp control range: RT +5℃~450℃
Speed ratio of range rising: 0.1-40℃/min
Gas Chromatograph, GC-901A
Detector: FID, TCD, ECD, FPD and NPD
Temp control area: 8-way
16 Steps of procedure temp rising
Temp control range: 4℃~450℃
Speed ratio of range rising: 0.1-60℃/min
Gas Chromatograph, GC-I112N
Detector: FID/TCD optional
20 groups of sample test mode memory function
Can match automatic sampler of various specifications
Gas Chromatograph GC-I112A
Detector: FID/TCD optional
Self-checking function & malfunction auto-identification
Manual Lifting Rotary Evaporator NMRE-104
Integrated digital speed and temperature display
PID temperature controller
Specialized motor for quiet and continuous operation
Acid and alkali resistant
PTFE discharge valve
Manual Lifting Rotary Evaporator NMRE-102
Integrated digital speed and temperature display
PID temperature controller
Specialized motor for quiet and continuous operation
Acid and alkali resistant
PTFE discharge valve
1 123 124 125 126 127 153
Are you interested in any product? GET QUOTE
Scroll to Top