Lab Ventilation Products
PCR Cabinet, LCB-VII Series
Energy-efficient DC blower HEPA filter (ISO Class 3 work-zone) Antimicrobial powder…
Enquire on WhatsAppEnquire
Vertical laminar negative pressure model
BSC biosafety cabinets are biological safety isolation equipment used in biological safety laboratories or other laboratories to protect personnel, tested samples and the environment. It can meet the operation of pathogenic body with risk level of 1, 2 and 3.
High-Quality & Ergonomic Construction
Energy-efficient
High security
Energy-efficient
High security
| Model | BSC-IIB2-5J |
| Cleanliness level | ISO level 4 |
| Filter efficiency | ≥99.9995%,@0.12μm |
| Classification | Class II Type B2 |
| Average flow rate of downdraft(m/s) | 0.25~0.40 |
| Average flow rate of inflow air(m/s) | ≥0.5 |
| Sound emission (dBA) | ≤67 |
| Vibration peak(μm) | ≤5 |
| Electricity | AC single-phase 220V/50Hz |
| Air balance biological protection | Personnel protection: a.The total number of colonies in the impact sampler:≤10CFU/time b.Total colony count of the slot sampler:≤5CFU/time |
| Product protection1-8CFU/ml(repeat 3times,5min/time) total number of colonies:≤5CFU/time | |
| Cross contamination protection 1-8CFU/ml(repeat 3times,5min/time) total number of colonies:≤5CFU/time | |
| Max power(KV·A) | ≤1.5(Spare socket included) |
| Weight(Kg) | 300/310 |
| Working zone area W*D*H(mm) | 1600*520*640 |
| External dimension W*D*H(mm) | 1765*760*2200 |
| Fluorescent lamp | 40W*2pcs |
| UV lamp | 40W*1pc |
| Illumination (Lux) | 900 |
| Supply and exhaust pipe diameter(mm) | Φ250 |
| Wind direction | Top in,top out |
| Model | BSC-IIB2-5J |
|---|---|
| Cleanliness level | ISO level 4 |
| Filter efficiency | ≥99.9995%,@0.12μm |
| Classification | Class II Type B2 |
| Average flow rate of downdraft(m/s) | 0.25~0.40 |
| Average flow rate of inflow air(m/s) | ≥0.5 |
| Sound emission (dBA) | ≤67 |
| Vibration peak(μm) | ≤5 |
| Electricity | AC single-phase 220V/50Hz |
| Air balance biological protection | Personnel protection:a.The total number of colonies in the impact sampler:≤10CFU/timeb.Total colony count of the slot sampler:≤5CFU/time |
| Max power(KV·A) | ≤1.5(Spare socket included) |
| Weight(Kg) | 300/310 |
| Working zone areaW*D*H(mm) | 1600*520*640 |
| External dimensionW*D*H(mm) | 1765*760*2200 |
| Fluorescent lamp | 40W*2pcs |
| UV lamp | 40W*1pc |
| Illumination (Lux) | 900 |
| Supply and exhaust pipe diameter(mm) | Φ250 |
| Wind direction | Top in,top out |
Specifications are provided by the manufacturer and may change. Confirm the exact configuration in your quotation.
Tell us how many units you need and where they will be installed. Your quotation will include delivery, installation and training options.
Lab Ventilation Products
Energy-efficient DC blower HEPA filter (ISO Class 3 work-zone) Antimicrobial powder…
Enquire on WhatsAppEnquireLab Ventilation Products
Vertical laminar negative pressure model
Enquire on WhatsAppEnquireLab Ventilation Products
Vertical laminar negative pressure model
Enquire on WhatsAppEnquireLab Ventilation Products
Vertical laminar negative pressure model
Enquire on WhatsAppEnquire